Case Library

Home > Resources > Case Library > Power Generation Case

Power Generation Case

Time: Jul 6 2026 Views: 79

PROJECT OVERVIEW

 

This case study presents a heat recovery system implemented in a coal-fired power generation facility operating under continuous high-load conditions.

 

The objective was to recover waste heat from flue gas while maintaining stable operation under corrosive, high-moisture exhaust conditions.

 

 

PROJECT CHALLENGE

 

High-Load Flue Gas Environment

 

The power plant presented the following operating conditions:

 

● Flue gas temperature: 130°C – 320°C

● Continuous 24/7 operation

● High moisture content in exhaust gas

● Presence of sulfur compounds (SO₂ / SO₃)

● Acid dew-point corrosion risk

● Large and stable gas flow volume

 

These conditions required a system capable of long-term stability and corrosion resistance.

 

 

ENGINEERING OBJECTIVE

 

The system was designed to achieve:

 

● maximum recovery of waste heat from flue gas

● stable operation under continuous high-load conditions

● resistance to acid dew-point corrosion

● low pressure drop for large gas flow systems

● long equipment lifecycle with minimal maintenance

 

 

SYSTEM SOLUTION

 

Fluoroplastic-Steel Composite Heat Recovery System

 

To meet operational requirements, a fluoroplastic-steel composite heat recovery system was deployed.

 

Structural Design

 

● Outer Layer: Fluoroplastic corrosion-resistant coating

● Inner Core: Steel structural support tube

 

This design ensured both corrosion protection and mechanical stability.

 

 

KEY ENGINEERING FEATURES

 

1. Corrosion Resistance

 

Fluoroplastic surface layer protects against acid condensation and chemical attack in low-temperature zones.

 

 

2. High Mechanical Strength

 

Steel core provides structural integrity under continuous pressure and thermal cycling.

 

 

3. Low Pressure Drop Design

 

Optimized flow channels ensure minimal resistance in large-volume flue gas systems.

 

 

4. Stable Heat Transfer Performance

 

System maintains consistent thermal performance under variable plant load conditions.

 

 

5. Long-Term Operational Stability

 

Designed for continuous operation in 24/7 industrial environments.

 

 

PERFORMANCE OUTCOME

 

After implementation, the system achieved:

 

● Improved waste heat recovery efficiency

● Stable long-term operation under corrosive conditions

● Reduced fouling compared to conventional steel systems

● Lower maintenance frequency

● Extended equipment service life

 

 

KEY ENGINEERING INSIGHT

 

Efficiency Is Limited by Corrosion, Not Heat Availability

 

In power generation systems, large amounts of recoverable heat are available.

 

The limiting factor is not energy supply, but:

 

● acid dew-point corrosion

● material degradation

● fouling under moisture conditions

 

Effective corrosion protection enables deeper and more stable heat recovery.

 

 

SYSTEM VALUE

 

The implemented system delivered:

 

● higher overall plant energy efficiency

● reduced fuel consumption for auxiliary heating

● improved environmental performance

● stable long-term operational reliability

 

 

CONCLUSION

 

Power generation systems represent one of the most important applications for industrial heat recovery technology.

 

By integrating corrosion-resistant materials with engineered system design, it is possible to achieve:

 

● higher energy utilization

● stable continuous operation

● improved lifecycle economics

● reduced maintenance requirements

 

 